by Regardt Voigt | Jul 24, 2022
ASCII data – which is used to be scanned into a SCADA system as a string, can be stored in both Binary string (16-Bits) or Hexadecimal format, inside of an D register.
by Regardt Voigt | Jun 11, 2021
It is possible by setting the scaling function or shift function from the parameter settings
by Regardt Voigt | Jun 11, 2021
Up to 4 high-speed pulse input/output modules FX5-16ET/ES-H,FX5-16ET/ESS-H* can be expanded, allowing a total of 16ch input (including built-in high-speed counter) *:High speed counter function of FX5-16ET/E□-H is equipped with 2ch
by Regardt Voigt | Jun 11, 2021
The high-speed counter supports 1-phase 1-input, 1-phase 2-input, 2-phase 2-input. The built-in counter in the CPU module can input up to 8ch. However, in the case of 32 point type CPU module, the maximum response frequency differs depending on the channel. –...
by Regardt Voigt | Jun 11, 2021
While the module configuration window is being displayed, the I/O assignment can be checked by selecting the following options from the menu bar: [Edit]→[XY Assignment Display]
by Regardt Voigt | Jun 11, 2021
Device backup is available without using a battery. However, to back up link register (W) and file register (R) devices, a battery is required.
by Regardt Voigt | Jun 11, 2021
FX3U-32BL can be used. The battery is not included with the CPU module during factory shipment. The battery can be used to increase the capacity of the latch device/label, as well as to maintain the clock data during power interruption.
by Regardt Voigt | Jun 10, 2021
32 stations can be connected when RS-485 port is used and only 1 station can be connected when RS-232 port is used.
by Regardt Voigt | Jun 9, 2021
The settings can be done using the parameter settings of GX Works3 or by settings the special relay/special registers. For further details please refer to MELSEC iQ-F FX5 User’s Manual (CPU Module Built-In Analog/Expansion-Adapter). 6 FX5U CPU MODULE BUILT-IN...
by Regardt Voigt | Jun 5, 2021
There are 3 main types of Melsec iQ-F CPUs, namely FX5U, FX5UC, and FX5UJ. Their differences\Specifications can be found HERE.
by Regardt Voigt | Jun 4, 2021
The wiring of an FX5 PLC includes the Digital Discrete Inputs\outputs and the Analog Continuous Inputs\Outputs. In addition, this includes the wiring of the RS-485 serial communication port on the PLC. The MELSEC iQ-F FX5U User’s Manual (Hardware) describes...
by Regardt Voigt | Jun 4, 2021
The following manual is specifically intended for that purpose: MELSEC iQ-F FX5 User’s Manual (Analog Control – Intelligent function module). It can be accessed here.