by Regardt Voigt | Feb 9, 2024
The FR-S500 VFD series is discontinued (Legacy). It is being replaced by the FR-D700 VFD series.
by Regardt Voigt | Feb 9, 2024
The FR-A024 series is legacy (discontinued) and is being replaced by the FR-E700 series. (Note also, that the E700 series is also discontinued, and therefore needs to be replaced by the FR-E800 series.)
by Regardt Voigt | Sep 23, 2022
The FR-E800-SCE VSD is a safety VSD therefore it does not have the STR or STF terminals. FR-E800-SCE Terminals Knowledge Base article: Why the FR-E800-SCE does not have STR and STF terminals (mymitsubishisupport.co.za) FR-E800-SCE Instruction Manual (Functional...
by Regardt Voigt | Jul 25, 2022
All FR-E800 inverters have a built-in Safety circuit. Please refer to the following manual for wiring reference: FR-E800 INSTRUCTION MANUAL (CONNECTION) (200V / 400V CLASS)...
by Regardt Voigt | Jul 24, 2022
ASCII data – which is used to be scanned into a SCADA system as a string, can be stored in both Binary string (16-Bits) or Hexadecimal format, inside of an D register.
by Regardt Voigt | Jul 1, 2021
The screen size cannot be enlarged or reduced because the video/RGB input screen (including multimedia) is hidden during the screen gesture mode.
by Regardt Voigt | Jun 30, 2021
The S901 variant of an MR-J2S is a specialized amplifier – and can only be supplied by the OEM.
by Regardt Voigt | Jun 21, 2021
The following document provides a clear breakdown of which Melsec-Q series modules are being replaced (due to EOL (End of Life), and which Melsec-Q series modules are the replacement options; Discontinuation Notice of the Some of the PLC QCPU by Mitsubishi Electric...
by Regardt Voigt | Jun 21, 2021
The following video describes these functions: Modbus Tutorial Point Table, Homing & Jog
by Regardt Voigt | Jun 20, 2021
No. For these Melsec PLC series – Only selected CPUs have CC-Link IE Field Basic Communication Protocol capabilities.
by Regardt Voigt | Jun 13, 2021
When multiple GT27, GT25, or GT21 models (Ethernet connection models) are connected to one PLC by Ethernet, the GOT communication port number is not required to be changed.
by Regardt Voigt | Jun 13, 2021
In the GOT2000 series, a commercially available wireless LAN access point compatible with IEEE802.11b/g/n standards can be used for the wireless LAN connection by using the wireless LAN communication unit (GT25-WLAN). However, there are the following restrictions. 1....
by Regardt Voigt | Jun 13, 2021
The license of the VNC server function for the GOT1000 series cannot be used for the GOT2000 series. Use the license for the GOT2000 series (GT25-VNCSKEY).
by Regardt Voigt | Jun 13, 2021
For the GOT2000 series, the following communication units for the GOT1000 series can be used. ■ GT27, GT25 (excluding GT2505, GT2510-WX, and GT2507-W) ・ GT15-QBUS, GT15-QBUS2, GT15-ABUS, GT15-ABUS2, GT15-75QBUSL, GT15-75QBUS2L, GT15-75ABUSL, GT15-75ABUS2L,...
by Regardt Voigt | Jun 13, 2021
The devices connectable to the GOT1000 series can be used with the GOT2000 series as well. However, some optional devices cannot be purchased due to the discontinuation of production. In such a case, please change the equipment configuration or connection type (for...
by Regardt Voigt | Jun 13, 2021
The rugged model supports the CC-Link IE Field Network Basic connection. Both Ethernet interface Port1 and Port2 are connectable to controllers that support the Ethernet and CC-Link IE Field Network Basic connections. The GOT2000 series operates as a slave station and...
by Regardt Voigt | Jun 13, 2021
The surface treatment of the front face of the rugged model is the AG (antiglare) treatment for both the environmental protection sheet and optional UV protective sheet. The environmental protection sheet and optional UV protective sheet are made from UV cutoff...
by Regardt Voigt | Jun 13, 2021
The UV protective sheet for the rugged model is used to protect the GOT from UV or damage. Since the UV protective sheet is replaceable, replacing the UV protective sheet can protect the GOT from degradation due to UV or damage.
by Regardt Voigt | Jun 13, 2021
The GT27, GT25, or GT21 model (Ethernet connection models) can monitor up to four controllers (four channels) (such as PLC CPU, temperature controller, and inverter) simultaneously by using the multi-channel function. Since channel 1 of the GOT is used to connect the...
by Regardt Voigt | Jun 11, 2021
This tool is for setting up the Ethernet/IP Communication Protocol on FX5. This tool can be downloaded here: FX5ENET-IP Configuration Tool 1.00 (note that a username and password will be required – therefore registration of an account will be required. This...