by Regardt Voigt | Jun 10, 2021
You can set IP addresses accessible to the CPU module and prevent unauthorized access to the CPU module. <Setting the IP filter function> [Navigation Window] -> [Parameter] -> [CPU Module] -> [Module Parameter] -> [Application Setting] ->...
by Regardt Voigt | Jun 10, 2021
The MELSEC iQ-R series CPU module has “IP filter function” and “remote password function” as security functions. With the “IP filter function”, you can set IP addresses accessible to the CPU module and prevent unauthorized access to...
by Regardt Voigt | Jun 9, 2021
Set modules in a module configuration diagram with GX Works3 and configure the inter-module synchronization setting. [Navigation Window] -> [Parameter] -> [System Parameter] -> [Synchronization Setting within the Modules] Set each item as...
by Regardt Voigt | Jun 9, 2021
“Network Parameter” in GX Works2 is “Module Parameter” of a “network module” in GX Works3. Click the items in the following order to display the setting window. <Setting parameters> [Navigation Window] -> [Parameter] ->...
by Regardt Voigt | Jun 9, 2021
You can display the setting window from a module configuration diagram or system parameters. <Displaying the setting window from a module configuration diagram> [Navigation Window] -> [Project] -> [Module Configuration] <Displaying the setting window...
by Regardt Voigt | Jun 9, 2021
“PC Parameter” in GX Works2 is “Parameter” in GX Works3. You can set the I/O assignment from “Module Configuration” or “System Parameter”. <Setting from the module configuration> [Navigation Window] -> [Project]...
by Regardt Voigt | Jun 5, 2021
GX Works3 and the MELSEC iQ-R series do not use actual devices as automatic assignment devices of local labels. The local labels use “label areas” in the “device/label memory”. You do not have to worry about devices such as when using GX...
by Regardt Voigt | Jun 5, 2021
You can display the setting window in the multiple CPU setting of system parameters – in GX Works3 <Multiple CPU setting> [Navigation Window] -> [Parameter] -> [System Parameter] -> [Multi CPU Setting]
by Regardt Voigt | Jun 5, 2021
From GX Works3 “Module Parameter” of the CPU module is the setting window. <Setting a built-in Ethernet port> [Navigation Window] -> [Parameter] -> [CPU Module] -> [Module Parameter]
by Regardt Voigt | Jun 5, 2021
No. Writing is not available when the model is different. Writing the parameter copy file using a USB memory device is available only for the same models. Otherwise, the error “Er.4” is displayed.
by Regardt Voigt | Jun 5, 2021
Some parameters are write-protected. (MR-J4/MR-J3: PA19) The parameter to be displayed is determined by the setting value of this parameter. Do as follows for MR Configurator2. Method 1: Set PA19 to “000E” in the list display and perform the parameter reading after...