by Regardt Voigt | Feb 9, 2024
The FR-S500 VFD series is discontinued (Legacy). It is being replaced by the FR-D700 VFD series.
by Regardt Voigt | Feb 9, 2024
The FR-A024 series is legacy (discontinued) and is being replaced by the FR-E700 series. (Note also, that the E700 series is also discontinued, and therefore needs to be replaced by the FR-E800 series.)
by Regardt Voigt | Jun 5, 2021
THIS website provides a quick breakdown of what the FREQROL FR-A800 series VFD Drive Inverters are about.
by Regardt Voigt | Jun 5, 2021
THIS guide contains a short summary of the FREQROL series VFD drive inverters available.
by Regardt Voigt | Jun 3, 2021
Automation hardware consists mainly out of the following components, as a core: PLC (Controller \ PAC) GOT (HMI \ Terminal) VFD (VSD \ Inverter \ Drive) Servo Robotics SCADA (Software)
by Regardt Voigt | Jun 2, 2021
A GOT (Graphic Operation Terminal), also referred to as a terminal or HMI) is a type of HMI (Human-Machine Interface). It is a piece of hardware, used as an intermediary device between a human (plant operator) and a system or a process (plant) for monitoring and...
by Regardt Voigt | Jun 2, 2021
A VFD (Variable Frequency Drive), also referred to as a VSD (Variable Speed Drive), inverter or drive, is a piece of hardware that is used to control the speed of an AC Induction motor. This is achieved by the VFD controlling the Frequency output (Hz) (in conjunction...
by Regardt Voigt | Jun 2, 2021
In one word, no. A VFD cannot be used as a replacement for a voltage transformer. If a motor requires 400Vac, then a 400Vac source is required as an input to the 400Vac VFD. The same goes for other voltage classes, The only exception to this rule is with phase number....
by Regardt Voigt | Jun 2, 2021
There are 4 classes for duty classification purposes. They are: SLD – Super light duty. (startup current: 110% for 60sec and 120% for 3sec – of the FLA value) LD – Light Duty (startup current: 120% for 60sec and 150% for 3sec – of the FLA...
by Regardt Voigt | Jun 2, 2021
kW (power) alone is not sufficient. One requires the motor nameplate details and the application details. From the motor nameplate, we can find the FLA current, voltage, phase number. From the application details we can determine the duty requirements of the inverter...
by Regardt Voigt | Jun 1, 2021
A highly recommended website to allow the user to access valuable training course materials on factory automation is the Mitsubishi e-learning resources – where free training courses can be attained; Link: Mitsubishi...