Investigating the AL.37 error of the Melservo MR-J3 servo amplifier.

Overview

The AL.37 error on Melservo amplifiers is quite common and needs to be resolved correctly before operation can be resumed.

AL.37 indicates a parameter error in the Mitsubishi MR-J3 servo amplifier. It triggers when a parameter is set outside its valid range, there’s a mismatch in parameter combinations, or settings don’t align with the hardware (e.g., wrong regenerative option or incompatible servo motor/amplifier pairing). This alarm is not stored in the history and can be cleared by resetting the alarm, CPU reset, or power cycling after corrections.

Materials on this error is available be sometimes unclear or spread out.
In this KBA, we will delve into the exact practical causes of this error and how to resolve it.