by Regardt Voigt | Dec 16, 2019 | FX5, GX Works 3, GX Works 3, High Speed I/O, Software
Mitsubishi iQ-F FX5U PLC Built-in High-Speed Counter Functionality & PLC interaction with encoder using pulse density. Introduction Just some additional information the Encoder interfacing to the Melsec iQ-FX5U PLC – please note that the following function blocks...
by Regardt Voigt | Dec 16, 2019 | CC-Link IE Field, Communication, GX Works 3, Melsec iQ-R, PLC
Melsec iQ-R Redundant Systems – with Analog IO (DA and AD) Introduction The following a summerized write-up on the implementation of a redundant Melsec iQ-R system. However, this PLC system is to accommodate Analog cards as well. (both DA and AD). It is known...
by Regardt Voigt | Dec 15, 2019 | Melsec-Q, PLC, Profinet
Melsec-Q, Profinet and ME1PN1FW-Q compatibility. Introduction The following is a short write-up of the Melsec-Q Profibus card and Q-series CPU compatibility. In addition some implementation pointers are pointed out, which includes the configuration requirements....
by Regardt Voigt | Dec 15, 2019 | FX5, GX Works 3, High Speed I/O
Melsec FX5 to Encoder Interconnection Introduction In connection to the application, which involves the interconnection between a Kuebler encoder and a Melsec iQ-F PLC – the following applies; There should be two methods in how to establish such a connection: Method...
by Regardt Voigt | Dec 15, 2019 | FX5, GX Works 3
GX Works3 – iQ-F FX5U – SPD FB – Pulse Density Setup Introduction In connection to the SPD function block utilization – setting up the PLC for Pulse Density counting; (can also be used for Encoder interfacing feedback). The following settings is...
by Regardt Voigt | Dec 15, 2019 | FX5, GX Works 3
Melsec iQ-F – High-speed counter inputs – Configuration settings Introduction A short discussion on the Configuration settings of a Melsec iQ-F PLC – High-Speed Counter Inputs – Using GX Works3. The High-Speed IO can be configured with the...
by Regardt Voigt | Dec 8, 2019 | FR-CS8xx, FX5, GX Works 3, PID Control, PLC, VSD
FX5U to FREQROL Inverter – Inverter Comms (Serial) PID Control – Implementation Strategy Introduction Here we will ONLY be looking at the strategic approach of interlinking an FX5U PLC CPU with a FREQROL Inverter using Inverter communication (Which is a serial...
by Regardt Voigt | Dec 8, 2019 | FX5, FX5-4DA, GX Works 3, PLC
Melsec iQ-F FX5-4DA card: Address Register Devices Introduction Herewith, some supplemental information on the configuration process of the FX5-4DA card with the FX5U PLC CPU. There are two main sets of registers that can be used with these modules; namely; Buffer...
by Regardt Voigt | Dec 8, 2019 | FX5, GX Works 3, MR Configurator, MR-J4s, PLC, Servos
MR-J4-A Servo interfacing with Melsec iQ-F FX5U Introduction A short description of some useful information in the MR-J4-A Servo interfacing process with Melsec iQ-F FX5U. You can use DABS command for absolute positioning in MR-J4-A. For this Utilization a – battery...
by Tanya Sauerman | Dec 4, 2019 | CC-Link, Communication, MELIPC
CC-Link IE Controller Network Overview The CC-Link IE Controller Network allows connection of MELSEC-Q series programmable controllers to the CC-Link IE Controller Network, realizing high-speed and large-volume data communications between the controllers in the...