To rewrite the current value, arbitrary values can be written using the DHCMOV instruction.
(Example) Set the current value of the high-speed counter ch1 to 0.[DHCMOV K0 SD4500 K0]
by Regardt Voigt | Jun 11, 2021 | 0 comments
To rewrite the current value, arbitrary values can be written using the DHCMOV instruction.
(Example) Set the current value of the high-speed counter ch1 to 0.[DHCMOV K0 SD4500 K0]