by Regardt Voigt | Oct 16, 2019 | FR-D7xx, PID Control, Speed Reference Control, VSD
Introduction A short description on how to apply a potentiometer (Analog input) to a FR-D700 inverter for speed reference purposes. The Parameterization initiation. The PU unit is to be set In PU Mode and Parameters Function. The following is the status of the...
by Regardt Voigt | Oct 8, 2019 | FR-E7xx, VSD
Introduction Some information on the explanation of the Current Average Value Monitor Signal – and in specific – that of the FR-E700 inverter, As for the parameters – the following are the main Parameters that are configurable. It must be noted that...
by Regardt Voigt | Sep 25, 2019 | FR Configurator, FR-A7xx, FR-A8xx, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, Software, VSD
Utilization of FR-Configurator and its VSD compatibility, OS Compatibility, Connection options and communication cabling requirements Introduction This section will cover the utilization of the FR-Configurator VFD parameterization configuration engineering software on...
by Regardt Voigt | Sep 22, 2019 | FR-A7xx, FR-A8xx, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
FR-D700 vs FR-CS80 and why the FR-D700 is superior to FR-CS80. Introduction We will be looking at two VFDs for this purposes – both of which are of the compact catagory. The intention is to provide factual clarity to aid in the decision making in the selection...
by Regardt Voigt | Sep 22, 2019 | CC-Link, FR-F8xx, VSD
CC-Link vs CC-Link IE Field Basic for FREQROL Inverters First some background (not all of it) The CC- Link Communication Protocol is a very wide protocol with plenty of variants and sub-variants. These sub-protocols are not directly inter-compatible – and...
by Regardt Voigt | Sep 16, 2019 | FR Configurator, FR-F8xx, VSD
FR-F800 (FREQROL) Inverter Drive series – Selection between two (or more) drives based on Duty requirements Selection of a suitable inverter drive. The following points are useful for such a process; Suppose you are required to select a VFD amongst two or more...
by Regardt Voigt | Jun 28, 2019 | FR-A8xx, FR-F8xx, Uncategorized, VSD
FR-F800 User Manual Enhanced Next Generation Energy Saving Drive ENERGY SAVING FUNCTIONS SUITABLE FOR VARIOUS SYSTEMS Standby power reduction: NEW With the 24 VDC external power supply, the input MC signal can be turned OFF after the motor is stopped, and turned ON...
by Regardt Voigt | Apr 3, 2019 | Communication, FR Configurator, Q Series, Uncategorized, VSD
Inverter Plug-in option – FR-A8NC – CC-Link Communication Card Setup This is a short condensed summary for the FR-A800 – FR-A8NC – CC-Link Communication Card. The Maximum number of units connected to one Master Station (CC-Link Ver 2.00) is 42 Units. This is...
by Regardt Voigt | Mar 27, 2019 | Communication, FR Configurator, FR-CS8xx, FX5, GX Works 3, GX Works 3
iQF-Series Modbus RTU Setup Introduction This Manual specifies the functionality and programming of the FX5U-PLC to connect with a CS80-VSD using Modbus-RTU. At the end of this manual, you will be able to send and receive messages from the FX5U-PLC to a CS80-VSD. This...
by Regardt Voigt | Mar 27, 2019 | Communication, FR Configurator, Uncategorized, VSD
How to setup Modbus communication from Mitsubishi FR-Series VSD to Adroit SCADA This is a very brief explanation on how to setup Modbus Ethernet communication between an Adroit SCADA application and a Mitsubishi F800-E2 drive. Modbus Ethernet addresses can be found in...