by Regardt Voigt | Oct 4, 2020 | FR Configurator, FR-A8xx, FR-Configurator2, FR-D7xx, FR-E7xx, FR-F8xx, VSD
Introduction A short discussion on the FREQROL Solar VFD Inverter Drive Series – pointing out the types and availability. Utilization These drives can be applied in remote and rural areas where grid power is unavailable. In addition, diesel generators are not...
by Regardt Voigt | Mar 31, 2020 | Communication, FR Configurator, FR-A7xx, FR-A8xx, FR-BR, FR-BU2, FR-Configurator2, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, Software, VSD
Introduction In this article we will provide the resources for the download of the FREQROL Inverter interface software. FREQROL inverters can be connected to an engineering software called FR-Configurator 2, for programming, parameterization, troubleshooting and...
by Regardt Voigt | Mar 17, 2020 | Communication, ENET, FR-A7xx, FR-A8xx, FR-BR, FR-BU2, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, GOT HMI, GOT SImple, GOT2000, GX Works 3, i-QR, Melsec iQ-R, Melsec-Q, PLC, Q Series, QSeries, Software, VSD
Introduction Network cable for Mitsubishi FA equipment is an important aspect to undersand for new users – in order to facility normal connection functions. This section is a short description in a FAQ style.of some basic (modern) communication connections and...
by Regardt Voigt | Mar 12, 2020 | Braking Resistor, Braking Unit, FR Configurator, FR-A7xx, FR-A8xx, FR-BR, FR-BU2, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
Introduction A short discussion on the Regenerative Over-voltage Trip during Deceleration or Stop – Drive Error (E.Ov3) for VFD Inverter (FREQROL) drives This type of error occurs when a VFD is requried to decelerate a load (or stop), within a time period which...
by Regardt Voigt | Oct 16, 2019 | FR-D7xx, PID Control, Speed Reference Control, VSD
Introduction A short description on how to apply a potentiometer (Analog input) to a FR-D700 inverter for speed reference purposes. The Parameterization initiation. The PU unit is to be set In PU Mode and Parameters Function. The following is the status of the...
by Regardt Voigt | Sep 25, 2019 | FR Configurator, FR-A7xx, FR-A8xx, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, Software, VSD
Utilization of FR-Configurator and its VSD compatibility, OS Compatibility, Connection options and communication cabling requirements Introduction This section will cover the utilization of the FR-Configurator VFD parameterization configuration engineering software on...
by Regardt Voigt | Sep 22, 2019 | FR-A7xx, FR-A8xx, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
FR-D700 vs FR-CS80 and why the FR-D700 is superior to FR-CS80. Introduction We will be looking at two VFDs for this purposes – both of which are of the compact catagory. The intention is to provide factual clarity to aid in the decision making in the selection...
by Regardt Voigt | Mar 27, 2019 | FR-A7xx, FR-A8xx, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
Choosing The Right Drive For The Right Application Introduction When choosing the correct Inverter drive for the correct application, we don’t always know which Inverter to use. The following is a guideline to help you with this choice: FR-A800 series Modular...
by Regardt Voigt | Mar 23, 2018 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
Introduction FR-E700 Inverter error codes can be found under troubleshooting section of the manual (attached). This section looks specifically at the Fault 7 based drive failure. Error E.7 Details As can be seen this error is related to electrical noise, external the...
by Regardt Voigt | Mar 21, 2018 | FR Configurator, FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
Read and export 700 series inverter Parameterization information Introduction It is often a requirement to document and record all the information available within an inverter but the question has often been how? Using the Mitsubishi FR Configurator software, the...