by Regardt Voigt | Mar 19, 2018 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
All 700 series inverter drives have I/O and it is now possible to monitor all I/O states from the parameter unit. Introduction Mitsubishi inverter drives have always had digital inputs and outputs (I/O), but has not always been possible to monitor the status of these...
by Regardt Voigt | Mar 17, 2018 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
All Mitsubishi inverters need the same basic setup as detailed below. Introduction All Mitsubishi inverters require a basic minimum setup. This basic setup is needed to match the inverter to the motor and to the application. In simple terms there are 9 – 10 basic...
by Regardt Voigt | Mar 6, 2018 | FR Configurator, FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, PID Control, VSD
Introduction The following is a short and practical description on how to setup VSD PID control via a FR-E700 inverter. Inverter Wiring Requirements; Inverter PID Control Parameterization: Reference Material For the FR-E700 applied manual – for reference...
by Regardt Voigt | Mar 6, 2018 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
Introduction All 700-Series inverters support a feature that displays information/error codes on the parameter unit. These display messages give information about the inverter and its status but are not alarm messages. Design Considerations An example of a non-alarm...
by Regardt Voigt | Mar 5, 2018 | FR Configurator, FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, Software, VSD
Introduction Normally VSDs are tested through the control of the parameter unit or external controls. FR-Configurator software gives another alternative for testing. Design Considerations A 700 series VSD can be controlled by the FR-Configurator software by following...
by Regardt Voigt | Mar 5, 2018 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, GOT HMI, GOT1000, GT2000, VSD
Introduction The GT1000 range of GOT/HMIs have a driver that supports connection to the 500 and 700 series Mitsubishi Electric VSDs. This provides the ability to interact with the VSD data and display information such as alarm codes. When displaying alarm codes the...
by Regardt Voigt | Feb 28, 2018 | FR-E7xx, FR-F7xx, FR-F8xx, VSD
Introduction Where several motors are to be speed controlled at the same speed it can be an efficient solution to install one suitably rated VSD drive to control these motors. Design Considerations The following points need to be considered in the design and...
by Regardt Voigt | Feb 27, 2018 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, Uncategorized, VSD
Introduction FR-Configurator SW3 software is the software tool that can be used with Mitsubishi Electric Factory Automation’s 700 series VSDs. This software supports many functions of which one is the test mode. Test mode allows the software to control and monitor the...
by Regardt Voigt | Feb 26, 2018 | Communication, FR-D7xx, FR-E7xx, VSD
Introduction Connecting FR-Configurator to the D700 and E700 VSDs is a little different to the F700 and A700 VSDs. This document explains what parameters need to be changed. Design Considerations D700 and E700 VSDs have 3 points of control as shown below. To allow PC...
by Regardt Voigt | Feb 21, 2018 | FR-E7xx, VSD
Inverter Output Shutoff signal (MBS Signal) This Parameter (Pr.17) allows for the user to add a stop button to the VSD. This works in conjunction with the STF (or STR) contacts. Terminal MRS may be user as follows; When hWhen Whewne sausdf Related...