by Regardt Voigt | Aug 21, 2022 | Adroit SCADA, ENET, FX3U
Introduction The interconnection between a Melsec FX3 PLC and Adroit SCADA using Ethernet-based communication protocol.Since, unlike the FX5 series, the FX3 series does not have a built-in ethernet communication port, an Ethernet communication adaptor (FX3U-ENET-ADP),...
by Regardt Voigt | Aug 21, 2022 | Adroit SCADA, FX5, GX Works 3, iQ-F
Introduction A quick write-up article that could be used to facilitate implementations with regards to the following: ModbusTCP communication-based data transfer (method1) Real values scanning The Method Procedure The FX5 (GX Works3) settingsFirst, we need to ensure...
by Regardt Voigt | Aug 21, 2022 | Adroit SCADA, FR-F8xx, VSD
Introduction This is a very brief explanation of how to setup Modbus Ethernet communication from Adroit SCADA to Mitsubishi F800-E2 drive.Modbus Ethernet addresses can be found in the A800-E/F800-E Ethernet Function Manual available on MyMitsubishi. However, the...
by Regardt Voigt | Aug 7, 2022 | Adroit SCADA, FX5, GX Works 3, iQ-F
Introduction In connection with the transferring of data between the FX5 and Adroit SCADA using Modbus TCP communication protocol – this write-up will provide the required information to facilitate this requirement. However, please note this is not recommended. The...
by Regardt Voigt | Aug 7, 2022 | Adroit SCADA, FX5U, iQ-F
Introduction There is another method for connecting a Melsec iQ-F PLC to the Adroit SCADA UI. The new method involves the utilization of the Modbus Device allocation Parameters table in GX Works3. This method is ideal if the user requires to scan Modbus device...
by Regardt Voigt | Jul 26, 2022 | Adroit SCADA, Agents, Communication, Ethernet, FX5, GX Works 3, Mitsubishi FA
Adroit SCADA to FX5 PLC connection Firstly The PLC needs to be configured so that it would be able to communicate to Adroit. The right IP address needs to be filled in as well the subnet mask needs to be correct according to your network settings. External Device...
by Regardt Voigt | Jul 24, 2022 | Adroit SCADA, Agents, FX5, GX Works 3, iQ-F
Introduction This document is compiled for the purposes for guiding the user on how to SCAN ASCII based strings inside of a PLC into Adroit SCADA via the string Agent. In this case the PLC being used is Melsec-iQ-F FX5 PLC, and the engineering software being used...
by Regardt Voigt | Jan 2, 2021 | Adroit SCADA, Agents, Communication, CUI, FR Configurator, FR-A8xx, FR-Configurator2, FR-E7xx, FR-E8xx, FR-F8xx, FREQROL, Modbus, Modbus TCP, SUI, VSD
Introduction The purpose of this article is to provide some SUPPLEMENTARY Hints and guidelines on setting up an Ethernet-based – Modbus TCP communication protocol interconnection between the FREQROL FR-F800FR-A800 inverter VFD and Adroit SCADA. Since the...
by Regardt Voigt | Apr 1, 2020 | Adroit SCADA, Agents, AMA, ARS, CUI, DBAccess, Eventlog, EventOutput, IPC, Lite (HMI), MAPS, MS Excel, Notify, ODBC, OLE-DB, Script, SQL Express, SUI
Introduction Sometimes it is required to extract Alarm activation based information from an Adroit Lite package. Let’s suppose that this Adroit Lite package is installed on an IPC bundle for this purpose. It must be pointed out that the Adroit Lite term actually...
by Regardt Voigt | Mar 31, 2020 | Adroit SCADA, ENET, FX5, GX Works 3, iQ-F, PLC, Software
Introduction This article is intended to provide a short-summary of how to connect a Melsec iQ-F to Adroit SCADA via an Ethernet communication standard. GX Works3 Configuration In GX Works 3 on the left in the Navigation menu go to Ethernet Port Insert the IP Address...