by Regardt Voigt | May 28, 2026 | Communication, FX5-20PG-D, FX5U, FX5UC, FX5UJ, iQ-F, Modbus, Modbus RTU
Introduction A short write-up explaining the functions, features, and implementation of the iQ-F PLC Modbus RTU Serial communication, using the built-in serial communication ports. Overview Modbus RTU serial communication on the Mitsubishi iQ-F FX5 PLC enables...
by Regardt Voigt | May 27, 2026 | FR-A8xx, FR-E8xx, FR-F8xx, FX5U, GX Works 3, iQ-F, VSD
Introduction This Knowledge base article investigates a method for controlling a FREQROL VSD via iQ-F PLC via CC- Link IE Field Basic Communication protocol Overview There are two ways to conclude the CC-Link IE Field Basic Communication setup between the FREQROL...
by Regardt Voigt | Aug 21, 2022 | Adroit SCADA, FX5, GX Works 3, iQ-F
Introduction A quick write-up article that could be used to facilitate implementations with regards to the following: ModbusTCP communication-based data transfer (method1) Real values scanning The Method Procedure The FX5 (GX Works3) settingsFirst, we need to ensure...
by Regardt Voigt | Aug 7, 2022 | Adroit SCADA, FX5, GX Works 3, iQ-F
Introduction In connection with the transferring of data between the FX5 and Adroit SCADA using Modbus TCP communication protocol – this write-up will provide the required information to facilitate this requirement. However, please note this is not recommended. The...
by Regardt Voigt | Aug 7, 2022 | Adroit SCADA, FX5U, iQ-F
Introduction There is another method for connecting a Melsec iQ-F PLC to the Adroit SCADA UI. The new method involves the utilization of the Modbus Device allocation Parameters table in GX Works3. This method is ideal if the user requires to scan Modbus device...
by Regardt Voigt | Jul 24, 2022 | Adroit SCADA, Agents, FX5, GX Works 3, iQ-F
Introduction This document is compiled for the purposes for guiding the user on how to SCAN ASCII based strings inside of a PLC into Adroit SCADA via the string Agent. In this case the PLC being used is Melsec-iQ-F FX5 PLC, and the engineering software being used...
by Regardt Voigt | May 31, 2021 | FR Configurator, FR-A8xx, FR-Configurator2, FR-E8xx, FR-F8xx, FREQROL, FX5-20PG-D, FX5U, FX5UC, FX5UJ, GX Works 3, iQ-F, VSD
Introduction This article is intended to provide some supplementary support information on the interconnection process between an FR-E800 series inverter and Melsec-iQ-F PLC – using CC-Link IE Field Basic network communication. GX Works3 – The Function...
by Regardt Voigt | May 31, 2021 | FX2N, FX3U, FX5, FX5-20PG-D, FX5U, FX5UC, FX5UJ, GX IEC, GX Works 2, GX Works 3, iQ-F
Introduction This article is intended to provide some information on the utilization of the FX-USB-AW Programming interface for the Melsec-FX PLC series. Installation of Drivers All the FX-USB-AW drivers and other can be downloaded from the link below; HERE....
by Regardt Voigt | May 17, 2021 | FX5U, FX5UC, FX5UJ, GX Works 3, iQ-F
Introduction Here we provide some technical and training resources for getting started purposes. Training resources will also be included to streamline the requirements. regarding Melsec iQ-F (GX Works3) training resources; The following is applicable: GX Work3 –...
by Regardt Voigt | Apr 14, 2021 | FX5, FX5U, GX Works 2, GX Works 3, GX Works 3, i-QR, iQ-F, Melsec iQ-R, Melsec-Q, PLC, Q Series, Software
Introduction A short comparison between two Melsec iQ-R memory cards types SD memory card vs SRAM SD memory card – NZ1MEM-2GBSD (284966) This is a 2GB SD memory card. Any PLC CPU that has an SD card slot – can use this card....