by Regardt Voigt | Feb 27, 2018 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, Uncategorized, VSD
Introduction FR-Configurator SW3 software is the software tool that can be used with Mitsubishi Electric Factory Automation’s 700 series VSDs. This software supports many functions of which one is the test mode. Test mode allows the software to control and monitor the...
by Regardt Voigt | Feb 26, 2018 | Communication, Convert PLC Applications, FR-F8xx, FX3U, FX5, PLC, VSD
Introduction Inter-device communication in the field of Industrial automation, in both factory automation and process control, This is the foundation of the integration philosophy, which is the future. In this particular application we will be looking at communicative...
by Regardt Voigt | Jan 23, 2018 | FR-F8xx, Uncategorized, VSD
Control System Application Scenario Requirements… In order to start – one has first to decide what the scenario of the control system is. Various factors are to be considered prior to parameterization in order to avoid ad-hoc applications. These include...
by Regardt Voigt | Jan 23, 2018 | Communication, FR-F7xx, FR-F8xx, GT Works 3, VSD
VSD Hardware and Connections When a VSD is to be configured and test – only from a communication aspect – it is required that the control board (CPU board) is to be powered up. It is not required that the entire VSD is to be powered for comms testing. To...
by Regardt Voigt | Jan 23, 2018 | FR-A8xx, FR-F8xx, Uncategorized, VSD
VSD Drive User Operation Mode selection Configuration Settings Parameterization – After VSD startup For the purpose of this scope – the operation mode at VSD Power – ON settings mainly consists out of two parameters that is being used on conjunction...
by Regardt Voigt | Dec 10, 2017 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
Method 1: PU (Programming unit) Operating Panel device. Limitations with this method: The inverter drives are required to be of the same model range. The parameter sets cannot be inter-transferred from different VSD models (and ranges) via the PU unit. Part 1:...
by Regardt Voigt | Oct 24, 2017 | FR-A7xx, FR-A8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
FR-E700 VSD – Drive-Run (VSD Running) state capture setup. This procedure to describe how the setupconfigure a VSD to provide a drive run status. Step 1: Ensure that the VSDPLC wiring is completed and correct. There are two options – the transistor relay and...
by Regardt Voigt | Oct 23, 2017 | FR-A8xx, FR-F8xx
This is for the setup of the Modbus TCP Communication setup (via Ethernet) of the FR-F700 VSD. Step 1: VSD Parameter Configuration Setup As a guideline on what to look for during the setup on the VSD drive for instance for Modbus TCP communication – the following is...