by Regardt Voigt | Feb 27, 2018 | ENET, FX3U, PLC
Introduction The FX3U-ENET module uses FX-Configurator-EN to setup all Ethernet settings including IP address. If however you do not have FX-Configurator-EN it is still possible to find out the IP address as shown below. Design Considerations An FX3U-ENET Ethernet...
by Regardt Voigt | Feb 26, 2018 | E Designer, E1000, GOT HMI, GX Developer, GX IEC
Introduction It is often the case that a PLC will be linked with an HMI and it is very helpful if both items can share the same variables list (Tag list or I/O list). Here we explain how this can be done. Design Considerations Firstly, it must be understood that the...
by Regardt Voigt | Feb 26, 2018 | Communication, FR-D7xx, FR-E7xx, VSD
Introduction Connecting FR-Configurator to the D700 and E700 VSDs is a little different to the F700 and A700 VSDs. This document explains what parameters need to be changed. Design Considerations D700 and E700 VSDs have 3 points of control as shown below. To allow PC...
by Regardt Voigt | Feb 26, 2018 | E1000, GOT HMI, GT2000
Introduction Under certain circumstances customers may wish to either show or hide an object on an HMI screen. This document explains how this can be achieved. Design Considerations There are two methods of showing and hiding object on screen depending on the GOT type...
by Regardt Voigt | Feb 26, 2018 | Communication, Convert PLC Applications, FR-F8xx, FX3U, FX5, PLC, VSD
Introduction Inter-device communication in the field of Industrial automation, in both factory automation and process control, This is the foundation of the integration philosophy, which is the future. In this particular application we will be looking at communicative...
by Regardt Voigt | Feb 26, 2018 | Uncategorized
Introduction There are 3 different types of memory cards available for Q-Series PLCs and it is important to choose the correct one as they do not all support the same features. The 3 types are SRAM (RAM), Flash (ROM) and ATA (ROM). Design Considerations It is...
by Regardt Voigt | Feb 26, 2018 | Uncategorized
Introduction It is sometimes a requirement of an HMI application to write a fixed or variable value to a data register in a PLC at the touch of a button. This document explains how this can be done with any current range GOT HMI. Design Considerations With an HMI...
by Regardt Voigt | Feb 26, 2018 | Uncategorized
Introduction The analog output of an inverter (VSD) is sometimes used as an input to third party devices to give an indication of inverter running speed, for example. To give an accurate indication of speed it is sometimes necessary to calibrate the analog signal as...
by Regardt Voigt | Feb 26, 2018 | Uncategorized
Introduction Many people know that PLCs are capable of working with numbers and mathematical calculations but the instruction set and rules can be confusing when trying to implement them in GX IEC Developer. Design Considerations Most Mitsubishi PLCs include 3...
by Regardt Voigt | Feb 26, 2018 | Uncategorized
Introduction It is inevitable when changing from a last generation product to a current generation product that some things may have changed. What this document offers is information on where to find conversion help. Design Considerations The FR-E700 instruction...
by Regardt Voigt | Feb 26, 2018 | Uncategorized
Introduction Every time a new version of GX IEC Developer is installed, the inevitable question is “how do I find out what is new and/or what has changed?”. This document aims to answer the question. Design Considerations When a new version of GX IEC Developer is...
by Regardt Voigt | Feb 26, 2018 | Uncategorized
Introduction To setup the FX3U-232ADP-MB Modbus module, it is necessary to initially configure the serial communication settings. this is relatively straight forward but there is a small issue to take care of when using GX IEC Developer. Design Considerations To...
by Regardt Voigt | Feb 26, 2018 | Servo Motors, Uncategorized
Introduction When it is not possible to locate a servo motor close to an MR-J3 servo amplifier, it is necessary to run long encoder cables. To avoid problems with electrical noise, it is necessary to use a 4 wire system for cables of lengths 30 meters and more. Design...
by Regardt Voigt | Feb 26, 2018 | FR-D7xx, VSD
Introduction Getting to drive parameters through the normal parameter unit can be a little slow so a quick-key access to popular parameters is helpful if you know where to find them. This example works on a D700 series drive but it will probably also work on the E700...
by Regardt Voigt | Feb 26, 2018 | GX IEC, Software
Introduction People often ask if there is any documentation of books on the IEC 61131-3 PLC programming standard and/or GX IEC Developer. The answer is yes. And the question is where? Design Considerations When GX Developer is installed, 3 documents are also...
by Regardt Voigt | Feb 26, 2018 | FX3U, GX Developer, PLC, Uncategorized
Introduction To make a Profibus Mater function correctly on an FX3U PLC, code is required. This involves reading the manual, understanding the example programs, understanding how the Profibus slaves work, and then writing PLC code to suit the slaves. If the user is...
by Regardt Voigt | Feb 26, 2018 | E Designer, Software
Introduction Exchanging E-Designer projects with other people is not as simple as sending the *.map file. An E-Designer project consist of the *.map file and several files and directories that usually contain things like bit map symbol files, OPC driver configuration...
by Regardt Voigt | Feb 26, 2018 | Convert PLC Applications
Introduction There is a small but constant demand from customers to be able to convert old F1 or F2 PLC applications to run on the current range FX PLC, but the question is how? Design Consideration The following conversion procedure is not the only way of PLC project...
by Regardt Voigt | Feb 26, 2018 | Testing
Introduction Many customers using GI fiber (62.5/125) for MELSEC Net PLC to PLC and/or PLC to MELSEC Net Remote I/O (A-Series, QnA Series and Qn PLCs), want to test the network on the bench before installing and end up purchasing or wanting to borrow cables with a DL6...
by Regardt Voigt | Feb 26, 2018 | IP Ratings, Servo Motors, Servo Systems, Servos
Introduction Mitsubishi provide servo motors with varying levels of IP rating. In most cases an addition to the part number is required to give a high IP rating to the motor shaft. This document details the differences. Design Constraints The IP rating for any item of...