by Regardt Voigt | Oct 6, 2020 | Melsec-Q, PLC, Q Series, Q68AD-G, Q68ADI, Q68ADV
Introduction A short discussion on the standard analog input modules of the Melsec-Q series PLC, By standard – we only refer to the highest density voltage and current modules. Note that: Current Analog Input is AI which is ADC which is analog to digital...
by Regardt Voigt | Oct 5, 2020 | Communication, FX5U, FX5UC, FX5UJ, GOT HMI, GOT SImple, GOT2000, GT Works 3, GT2000, GX Works 3, GX Works 3, iQ-F, SoftGOT
Introduction This article is intended to provide the applicable user with some guidance in the interconnection of Melsec iQ-FX5U – and the GOT2000 via Ethernet communication medium. But first, some important disclaimers. When it comes to inter-device communication...
by Regardt Voigt | Oct 4, 2020 | FR-D700-E12, FR-D7xx, FR-E700=E12, FR-E7xx, Solar drives, VSD
Introduction Mitsubishi has released specialized solar compatible VFD inverter drives, specifically designed for solar pumping applications. The following is a short article intended to provide some information and clarity. Solar Inverter Features The following is a...
by Regardt Voigt | Oct 4, 2020 | FR Configurator, FR-Configurator2, FR-D700-E12, FR-D7xx, FR-E700=E12, FR-E7xx, Solar drives, VSD
Introduction With the release of the new FREQROL Solar Pumping VFD inverter drives series, being the FR-E700-E12 and FR-D700-E12 series’, some information is required in terms of the comparison with the standard FREQROL inverter drives series. This article will...
by Regardt Voigt | Oct 4, 2020 | FR Configurator, FR-A8xx, FR-Configurator2, FR-D7xx, FR-E7xx, FR-F8xx, VSD
Introduction A short discussion on the FREQROL Solar VFD Inverter Drive Series – pointing out the types and availability. Utilization These drives can be applied in remote and rural areas where grid power is unavailable. In addition, diesel generators are not...
by Regardt Voigt | Oct 3, 2020 | Mitsubishi CNC drives, Servo Motors, Servos
Introduction This short article is intended to provide some basic guidelines for the replacement of Mitsubishi CNC drives, in terms of prerequisites for a quotation. Guideline When contacting your Adroit Technologies Sales Engineer representative for a CNC drive...
by Regardt Voigt | Oct 3, 2020 | CC-Link, CC-Link IE Field, Communication, DNP3, Ethernet, FX5, FX5U, FX5UC, FX5UJ, GPRS, GX Works 3, iQ-F, Modbus, Modbus RTU, Modbus TCP, PLC, Profinet, RS-232, RS-422, Serial
Introduction A short discussion on the available communication protocols related to the Melsec iQ-F FX5U PLC CPU. It stands to reason that this CPU (just like any other CPU) supports a finite number, predefined communication protocols. More details are being given...
by Regardt Voigt | Oct 2, 2020 | FX2N, FX3U, GX Works 2, GX Works 3, Melsec-FX, PLC
Introduction Melsec FX PLCs require the FX-USB-AW Interface to connect with, via GX Works2, via a PC or Laptop.However, this interface requires the correct drivers. Different Operating Systems require different drivers. This article will assist the users in attaining...
by Regardt Voigt | Apr 14, 2020 | FX3U, FX5, GX Developer, GX Works 2, GX Works 3, i-QR, iQ-F, Melsec iQ-R, Melsec-FX, Melsec-Q, Mitsubishi EMEA FA Common Platform, Q Series
Introduction Some essential information regarding the GX Works3 – Engineering Software Package; This software is not freeware but commercial. Upon purchase You get two licenses. (However, a five license version is also available) The licenses are not annual but...
by Regardt Voigt | Apr 14, 2020 | FX5, FX5U, FX5UC, FX5UJ, GX Works 3, iQ-F, PLC
Introduction Here will discuss some points on the FX5UJ, in terms of features and functions, compared to that of the FX5U. As such – most of the features discussed – will be that of the FX5UJ. Wiring Connections (Digital Discrete IO) Here we will be...
by Regardt Voigt | Apr 14, 2020 | GX Works 3, Melsec iQ-R, PLC
Introduction A summarized topic of the Melsec iQ-R PLC CPU, and its specifications thereof. Melsec iQ-R CPU Standard and Ethernet Module Specifications The following CPU module specifications are applicable: CPU Module Startup Comparison The following hardware...
by Regardt Voigt | Apr 8, 2020 | GX Works 2, Melsec-Q, PLC, Q Series, QSeries
Introduction This is a short-write up on the Melsec-Q series PLC CPU, depicting differences, specifications, discontinuation and replacements, and model identification. Basic Model QCPU Herewith the Basic Model Performance Specifications: High Performance Model QCPU...
by Regardt Voigt | Apr 2, 2020 | Convert PLC Applications, FX2N, FX3U, FX5, GX Works 2, GX Works 3, i-QR, iQ-F, Melsec iQ-R, Melsec-A, Melsec-FX, Melsec-Q, PID Control, PLC, Q Series, QSeries, Software, VSD
DATATYPES In the digital world, logic is the dictating force in order for performance to exist. The language at which data is being put in transit is being done so via the values being stored into the relevant datatypes. In general, the following datatypes are...
by Regardt Voigt | Apr 1, 2020 | FX2N, FX3U, FX3U-4AD-ADP, GX Works 2, Melsec-FX, PLC, Software
Introduction A short discussion on how to utilize teh FX3U-4AD-ADP Analog input card with Melsec-FX CPUs. The System The following is a breakdown of the System applicable; PLC CPU version compatility The PLC CPU versions for compatibility of analog inputt card...
by Regardt Voigt | Apr 1, 2020 | Adroit SCADA, Agents, AMA, ARS, CUI, DBAccess, Eventlog, EventOutput, IPC, Lite (HMI), MAPS, MS Excel, Notify, ODBC, OLE-DB, Script, SQL Express, SUI
Introduction Sometimes it is required to extract Alarm activation based information from an Adroit Lite package. Let’s suppose that this Adroit Lite package is installed on an IPC bundle for this purpose. It must be pointed out that the Adroit Lite term actually...
by Regardt Voigt | Mar 31, 2020 | FX5, GX Works 2, GX Works 3, GX Works 3, i-QR, iQ-F, Melsec iQ-R, Melsec-Q, PLC, Q Series, QSeries, Software
Introduction GX Works is a commercial software – and not free-ly available. This makes sense, given the amount of features and functionality one gets with the software. Upon the purchasing of the license(s) – the software can be registered online. Free...
by Regardt Voigt | Mar 31, 2020 | Communication, FR Configurator, FR-A7xx, FR-A8xx, FR-BR, FR-BU2, FR-Configurator2, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, Software, VSD
Introduction In this article we will provide the resources for the download of the FREQROL Inverter interface software. FREQROL inverters can be connected to an engineering software called FR-Configurator 2, for programming, parameterization, troubleshooting and...
by Regardt Voigt | Mar 31, 2020 | Communication, DNP3, ENET, Ethernet, FX3U, FX3U-4DA, FX5, FX5-4DA, GPRS, GX Works 2, GX Works 3, iQ-F, ME-RTU, Modbus, Modbus RTU, Modbus TCP, PLC, real-time clock, RS-232, RS-422, RTU, Serial
Introduction RTUs – being a Remote Terminal Unit – is an essential part of distributed PLC and IO systems.This is a concise discussion on the ME-RTU module, its application options, including specifications, features and functionalities. The following unit...
by Regardt Voigt | Mar 31, 2020 | Adroit SCADA, ENET, FX5, GX Works 3, iQ-F, PLC, Software
Introduction This article is intended to provide a short-summary of how to connect a Melsec iQ-F to Adroit SCADA via an Ethernet communication standard. GX Works3 Configuration In GX Works 3 on the left in the Navigation menu go to Ethernet Port Insert the IP Address...
by Regardt Voigt | Mar 31, 2020 | F940GOT-LWD-E, GOT HMI, GOT SImple, GOT-F900, GOT2000, GT Works 3, GT2000
Introduction As mentioned earlier, the GOT-F900 series is long since being discontinued. It is not being manufactured anymore, nor sold. No parts are available, and technical support on this product has seized. The next logical step would be to upgrademigrate the...