by Regardt Voigt | Mar 30, 2020 | E1000, F940GOT-LWD-E, GOT HMI, GOT-F900, GOT1000, GOT2000, GT Works 3, GT2000, PM-20BL
Introduction The GOT-F900 HMI is long since being discontinued. These units are not be manufactured, sold or supported anymore. That said – there are still plenty of these units left in the plants, processes and systems using these old discontinued GOTs. This...
by Regardt Voigt | Mar 30, 2020 | A172SHCPUN, GX Works 2, Melsec-A, Melsec-Q, MR-J2s, MR-J4s, PLC, Q Series, QSeries, Servo Systems, Servos, Software, SW0NX-SV22C, SW0SRX-SV22C, SW3RN-SV22C
Introduction The Melsec-A series PLC series is long since being discontinued, from manufacturing, supply and support perspective. Nonetheless, there are still some Melsec-A series PLCs in the processes and systems. This particular article is addressing the Motion...
by Regardt Voigt | Mar 30, 2020 | FX2N, FX3U, FX5, GX Works 2, GX Works 3, GX Works 3, i-QR, iQ-F, Melsec iQ-R, Melsec-Q, PLC, Q Series, Software
Introduction This is a short summary discussion on the Melsec PLC series engineering software, and which modules are compatible with whcih versions of engineering software. The following are 2nd generation PLCs – and they are programmed via GX Works2 Melsec FX –...
by Regardt Voigt | Mar 18, 2020 | FX5, FX5-20PG-D, FX5-20PG-P, High Speed I/O, iQ-F, MR-J2s, MR-J4s, PLC, Servo Systems, Servos
Introduction The interconnection of a PLC to a Servo amplifier or other front-end device, via a digital discrete pulse-train output – is catagory of High-speed outputs. In the case for Servo-amplifier control, this is known as positioning. This section will...
by Regardt Voigt | Mar 17, 2020 | Communication, ENET, FR-A7xx, FR-A8xx, FR-BR, FR-BU2, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, GOT HMI, GOT SImple, GOT2000, GX Works 3, i-QR, Melsec iQ-R, Melsec-Q, PLC, Q Series, QSeries, Software, VSD
Introduction Network cable for Mitsubishi FA equipment is an important aspect to undersand for new users – in order to facility normal connection functions. This section is a short description in a FAQ style.of some basic (modern) communication connections and...
by Regardt Voigt | Mar 12, 2020 | FX5, GX Works 3, GX Works 3, PLC, Software
Introduction This page focusses on the what the possible reasons could be when the FX5 PLC does not automatically go into RUN mode – after startup.For the most part – we will assume that no PLC errors are being detected. The following Root cause...
by Regardt Voigt | Mar 12, 2020 | Braking Resistor, Braking Unit, FR Configurator, FR-A7xx, FR-A8xx, FR-BR, FR-BU2, FR-CS8xx, FR-D7xx, FR-E7xx, FR-F7xx, FR-F8xx, VSD
Introduction A short discussion on the Regenerative Over-voltage Trip during Deceleration or Stop – Drive Error (E.Ov3) for VFD Inverter (FREQROL) drives This type of error occurs when a VFD is requried to decelerate a load (or stop), within a time period which...
by Regardt Voigt | Mar 5, 2020 | Convert PLC Applications, ENET, Extensions, FX2N, FX3U, FX3U-4DA, FX5, FX5-4DA, GT Works 3, GX Developer, GX IEC, GX Works 2, GX Works 3, High Speed I/O, i-QR, Melsec iQ-R, Melsec-Q, PLC, Q Series, QSeries, Software
Introduction A squick set of pointers and hints for the Upgrade Migration from a compact Melsec PLC to a different Melsec PLC Options. Traditionally – the following migration paths are automatically accomodated (For the most part); Melsec-FX is being...
by Regardt Voigt | Mar 5, 2020 | Extensions, GX Works 2, Melsec-Q, PLC, Q Series, Software
Introduction A short description of the Melsec-Q IO – Discrete IO Extension, connectors and cables of some standard modules. The following applies: QX81 (Discrete Input) – A6TBX36-E (Connector) – AC20TB-E (Cable) QY81P (Discrete...
by Regardt Voigt | Mar 4, 2020 | CC-Link IE Field, GX Works 3, GX Works 3, i-QR, Melsec iQ-R
Introduction A short discussion on the Configuration process for a Melsec iQ-R Safety Controller to Safety RIO interconnection via CC-Link IE Field Network, with the purpose to provide some direction and guidance. This entire setup is to be engaged holistically, and...
by Regardt Voigt | Mar 4, 2020 | MR Configurator, MR-J2s, MR-J4s, Servo Motors, Servo Systems, Servos, Uncategorized
Introduction As is known by now, the MR-J2s and MR-J3 Meleservo series are being phased out very quickly and being replaced with MR-J4 (and MR-J5) Melservo series For this purpose – migration renewal tools are available. (More detail on another post). Provision...
by Regardt Voigt | Feb 11, 2020 | CC-Link, Communication, GX Works 2, Q Series
Q-SERIES PLC TO REMOTE CC-LINK IO-CARD SETUP Introduction This Manual specifies a setup example between a Mitsubishi Q-Series PLC and a Remote CC-Link IO. At the end of this manual, you will be able to send and receive messages between a Mitsubishi Q-Series PLC and a...
by Regardt Voigt | Dec 16, 2019 | FX5, GX Works 3, GX Works 3, High Speed I/O, Software
Mitsubishi iQ-F FX5U PLC Built-in High-Speed Counter Functionality & PLC interaction with encoder using pulse density. Introduction Just some additional information the Encoder interfacing to the Melsec iQ-FX5U PLC – please note that the following function blocks...
by Regardt Voigt | Dec 16, 2019 | CC-Link IE Field, Communication, GX Works 3, Melsec iQ-R, PLC
Melsec iQ-R Redundant Systems – with Analog IO (DA and AD) Introduction The following a summerized write-up on the implementation of a redundant Melsec iQ-R system. However, this PLC system is to accommodate Analog cards as well. (both DA and AD). It is known...
by Regardt Voigt | Dec 15, 2019 | Melsec-Q, PLC, Profinet
Melsec-Q, Profinet and ME1PN1FW-Q compatibility. Introduction The following is a short write-up of the Melsec-Q Profibus card and Q-series CPU compatibility. In addition some implementation pointers are pointed out, which includes the configuration requirements....
by Regardt Voigt | Dec 15, 2019 | FX5, GX Works 3, High Speed I/O
Melsec FX5 to Encoder Interconnection Introduction In connection to the application, which involves the interconnection between a Kuebler encoder and a Melsec iQ-F PLC – the following applies; There should be two methods in how to establish such a connection: Method...
by Regardt Voigt | Dec 15, 2019 | FX5, GX Works 3
GX Works3 – iQ-F FX5U – SPD FB – Pulse Density Setup Introduction In connection to the SPD function block utilization – setting up the PLC for Pulse Density counting; (can also be used for Encoder interfacing feedback). The following settings is...
by Regardt Voigt | Dec 15, 2019 | FX5, GX Works 3
Melsec iQ-F – High-speed counter inputs – Configuration settings Introduction A short discussion on the Configuration settings of a Melsec iQ-F PLC – High-Speed Counter Inputs – Using GX Works3. The High-Speed IO can be configured with the...
by Regardt Voigt | Dec 8, 2019 | FR-CS8xx, FX5, GX Works 3, PID Control, PLC, VSD
FX5U to FREQROL Inverter – Inverter Comms (Serial) PID Control – Implementation Strategy Introduction Here we will ONLY be looking at the strategic approach of interlinking an FX5U PLC CPU with a FREQROL Inverter using Inverter communication (Which is a serial...
by Regardt Voigt | Dec 8, 2019 | FX5, FX5-4DA, GX Works 3, PLC
Melsec iQ-F FX5-4DA card: Address Register Devices Introduction Herewith, some supplemental information on the configuration process of the FX5-4DA card with the FX5U PLC CPU. There are two main sets of registers that can be used with these modules; namely; Buffer...